DocumentCode :
2554219
Title :
CT reconstruction from few-views by Anisotropic Total Variation minimization
Author :
Debatin, Maurice ; Zygmanski, Piotr ; Stsepankou, Dzmitry ; Hesser, Jurgen
Author_Institution :
Dept. of Radiat. Oncology, Univ. of Heidelberg, Mannheim, Germany
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
2295
Lastpage :
2296
Abstract :
Dose reduction is an important factor in medical imaging, One of the key strategies to reduce the dose in CT reconstruction is undersampling, The recently proposed Compressed Sensing (CS) paradigm has shown that nearly exact CT reconstructions can be obtained from highly under-sampled projection sets using e.g. regularized iterative reconstruction algorithms. For the regularization, the standard Total Variation (TV) minimization method is commonly applied. The TV has a sparse setting and can therefore be utilized in the CS framework. It can smooth undesired discontinuities related to noise and preserve edges of the field-of-interest objects. It has developed a de facto standard method in CS based CT reconstructions. Nevertheless, the utilization of the Total Variation method has several drawbacks. One of these is oversmoothing of some fine objects, structures and textures and at the same time great spatial resolution loss. The purpose of this work is to develop a new Anisotropic Total Variation (ATV) method that can overcome these disadvantages and produce strong results in the sparse environment. In this work it will be shown that the usage of ATV regularization leads to edges, objects and fine structures which are sharper and clearer in contrast to the standard TV method. In addition to that the spatial resolution for the ATV method is much higher than for the TV method. The performance of both methods will be evaluated visually by means of digital simulated data, as well as real data scans obtained from an Elekta cone-beam synergy system.
Keywords :
compressed sensing; computerised tomography; edge detection; image reconstruction; image resolution; image texture; iterative methods; medical image processing; minimisation; smoothing methods; variational techniques; ATV regularization; CS based CT reconstruction; CS framework; Elekta cone-beam synergy system; anisotropic total variation minimization; compressed sensing paradigm; de facto standard method; digital simulated data; dose reduction; edge preserving; field-of-interest object; highly under-sampled projection set; medical imaging; object structure; object texture; oversmoothing; regularized iterative reconstruction algorithm; sparse setting; spatial resolution loss; standard total variation minimization method; Anisotropic Total Variation Minimization; CBCT; Compressed Sensing; low-dose; spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551521
Filename :
6551521
Link To Document :
بازگشت