DocumentCode
2555357
Title
Specifying control of immunity to power line switching transients
Author
Javor, Ken
Author_Institution
EMC Compliance, Huntsville, AL, USA
fYear
1994
fDate
22-26 Aug 1994
Firstpage
196
Lastpage
201
Abstract
Theoretical and experimental investigation reveals discrepancies between common spike immunity requirements and real switching transients. In particular, excessively low source impedance forces unnecessary over-design of EMI filters. A test method using a LISN (line impedance stabilisation network) and switched high current load is investigated as an alternative transient generator, and the effect on filter-design is noted. This test method has dual advantages: a) it simulates real world transients in both amplitude, duration and source impedance, and b) it uses commonly available EMI test equipment and requires no expensive single application acquisitions
Keywords
electric impedance; electromagnetic interference; filters; power system transients; switching circuits; transient analysis; EMI filters; EMI test equipment; LISN; line impedance stabilisation network; low source impedance; power line switching transients immunity; source impedance; spike immunity requirements; switched high current load; transient generator; Electromagnetic compatibility; Electromagnetic transients; Filters; Immunity testing; Impedance; Lightning; Power system transients; Shape; Voltage; Wiring;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1994. Symposium Record. Compatibility in the Loop., IEEE International Symposium on
Conference_Location
Chicago, IL
Print_ISBN
0-7803-1398-4
Type
conf
DOI
10.1109/ISEMC.1994.385617
Filename
385617
Link To Document