Title :
Signal characteristics study of continuous scintillator CCD-based single photon counting (SPC) detector
Author :
Qingyang Wei ; Jain, Abhishek ; Ionita, Ciprian N. ; Xiao Deng ; Tiantian Dai ; Tianyu Ma ; Yaqiang Liu ; Bednarek, D.R. ; Rudin, S. ; Rutao Yao
Author_Institution :
Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
fDate :
Oct. 27 2012-Nov. 3 2012
Abstract :
Detectors with thin continuous scintillators and (charge coupled devices) CCDs have been used for animal SPECT imaging for their high intrinsic resolution. Thicker scintillators augment detection efficiency but also increase the light spread and difficulty in identification of gamma events. The objective of this work was to study the characteristics of the detector composed of a continuous CsI(TI) scintillator, a fiber optic taper, a light image intensifier (LII), and a CCD image sensor. Continuous scintillator was chosen for its simple optical propagation model. The large variable gain of the LII enables the detector to work in single photon counting (SPC) mode which may recover the light spread of each scintillation event to improve the detector´s spatial resolution. The energy of gamma-rays studied was 140 keV. A linear cascade model was used to quantify the photon propagation through each component of the detector. For a continuous scintillator, its modular transfer function (MTF) was modeled by an analytical function. The MTFs of other detector components were obtained from the results of prior reports. With the cascade model, the detector´s overall point spread function was derived and mixed with Poisson noise and CCD read-out noise. A local-maxima based peak detection algorithm was used to identify the photon events in each frame acquired. A simulation study with a limited number of photons showed that when the light-spread distance augmented from 0.8 to 1.0 mm, the fraction of noise equivalent count decreased from 0.73 to 0.06. So the thickness limit for a continuous scintillator with the detector configuration studied was about 0.8 mm.
Keywords :
CCD image sensors; optical transfer function; photodetectors; photon counting; readout electronics; scintillation counters; single photon emission computed tomography; CCD image sensor; CCD read-out noise; MTF; Poisson noise; SPC mode; animal SPECT imaging; charge coupled devices; continuous CsI(TI) scintillator; continuous scintillators; detector configuration; electron volt energy 140 keV; gamma events; gamma-ray energy; large variable gain; light spread; linear cascade model; local-maxima based peak detection algorithm; modular transfer function; noise equivalent count; optical propagation model; photon events; photon propagation; point spread function; signal characteristics; single photon counting mode; thicker scintillators;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA