DocumentCode :
255685
Title :
LCL topology variability in the VSI-LCL induction heating system
Author :
Dzieniakowski, Maciej A.
Author_Institution :
Inst. of Control & Ind. Electron., Warsaw Univ. of Technol., Warsaw, Poland
fYear :
2014
fDate :
26-28 Aug. 2014
Firstpage :
1
Lastpage :
7
Abstract :
The voltage fed inverter with LCL resonant load has been considered. The paper presents the load topology changes phenomenon, which leads in VSI-LCL converter properties alteration. The phenomenon has been investigated and the causes of variability are described. The chosen parameters of LCL variable topology circuit are analytically defined. The range values of new parameters are determined and illustrated. The new variable frequency converter concept, based on topology variability phenomenon is presented and discussed. The numerical calculations results and the laboratory tests are shown.
Keywords :
LC circuits; induction heating; invertors; network topology; resonant power convertors; LCL resonant load; LCL variable topology circuit; VSI-LCL converter properties alteration; VSI-LCL induction heating system; load topology changes phenomenon; topology variability phenomenon; variable frequency converter concept; voltage fed inverter; Electromagnetic heating; Frequency conversion; Inverters; RLC circuits; Resonant frequency; Topology; Voltage control; LCL resonant converter; converter control; induction heating; topology variability; voltage source inverter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
Conference_Location :
Lappeenranta
Type :
conf
DOI :
10.1109/EPE.2014.6910876
Filename :
6910876
Link To Document :
بازگشت