Abstract :
The measurement accuracy of time domain systems for microwave tomography are evaluated through system level simulations and compared with that of a network analyzer based frequency domain system. In the analysis, both a time domain ultra-wideband (UWB) impulse and multiband system architectures are considered. It is shown that the measurement error of the time domain systems mainly comes from analog to digital (A/D) conversion. For a simple comparison case, the relative measurement error involved in an estimated object response signal from the time domain UWB impulse system and UWB multiband system measurements are around three times and ten times higher than that from frequency domain system.
Keywords :
analogue-digital conversion; microwave imaging; time-frequency analysis; tomography; ultra wideband technology; analog to digital conversion; frequency domain system; microwave tomography; multiband system architectures; network analyzer; time domain UWB impulse system; time domain measurement systems; time domain ultra-wideband impulse; Analytical models; Frequency domain analysis; Frequency estimation; Frequency measurement; Measurement errors; Microwave measurements; Time domain analysis; Time measurement; Tomography; Ultra wideband technology; Measurement errors; medical imaging; microwave imaging; system modeling; time domain measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 2009. MTT '09. IEEE MTT-S International
Conference_Location :
Boston, MA
ISSN :
0149-645X
Print_ISBN :
978-1-4244-2803-8
Electronic_ISBN :
0149-645X
Type :
conf
DOI :
10.1109/MWSYM.2009.5165978
Filename :
5165978
Link To Document :
بازگشت