Title :
Development of a MPPC-based DOI-PET module with submillimeter 3-D resolution
Author :
Kishimoto, Akihiro ; Kataoka, J. ; Kato, Toshihiko ; Miura, Tsuyoshi ; Nakamori, Toshiki ; Kamada, K. ; Nakamura, Shigenari ; Sato, Kiminori ; Ishikawa, Yozo ; Yamamura, Kazuya ; Yamamoto, Seiichi
Author_Institution :
Res. Inst. for Sci. & Eng., Waseda Univ., Tokyo, Japan
fDate :
Oct. 27 2012-Nov. 3 2012
Abstract :
We are proposing a novel design for a module with depth of interaction (DOI) capability for gamma rays by measuring the pulse-height ratio of double-sided Multi-Pixel Photon Counters (MPPCs) coupled at both ends of a scintillation crystal block. Thanks to newly developed monolithic MPPC arrays consisting of 4 × 4 channels with a three-side buttable package, the module is very thin and compact, thereby enabling less dead space between each module when arranged into a fully designed gantry. To demonstrate our concept of a DOI measuring technique, we first made a 1-D crystal array consisting of five Ce-doped Gd3Al2Ga3O12 (Ce:GAGG) cubic crystals measuring 3 × 3 × 3 mm3 in size, separated by a layer of air. When the light signals output from both ends are read with the MPPCs, the position of each crystal is clearly distinguished with a spatial uncertainty of 0.48 ± 0.03 mm. For 3-D measurements, we then fabricated three different type arrays: [A] 4 × 4 × 4 matrix of 3 × 3 × 3 mm3 pixels, [B] 5 × 5 × 5 matrix of 2 × 2 × 2 mm3 pixels, and [C] 10 × 10 × 10 matrix of 1 × 1 × 1 mm3 pixels, with each pixel divided by a BaSO4 reflector in the 2-D direction and by a layer of air in the DOI direction. We demonstrated that the 3-D position of each Ce:GAGG pixel was clearly distinguished when illuminated by 662 keV gamma rays uniformly. Average energy resolutions of 9.8 ± 0.8 %,9.8 ± 0.9 %, and 13.2 ± 1.7 % were obtained for types A, B and C, respectively. These results suggest that our proposed method is simple and offers promise in achieving 1 mm 3-D spatial resolution for future medical imaging, partic
Keywords :
aluminium compounds; cerium; gadolinium compounds; positron emission tomography; scintillation; 1D crystal array; Gd3Al2Ga3O12:Ce; MPPC-based DOl-PET module; cubic crystals; depth-of-interaction; double-sided multipixel photon counters; gamma rays; monolithic MPPC arrays; positron emission tomography; pulse-height ratio; scintillation crystal block; submillimeter 3D resolution; three-side buttable package;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-4673-2028-3
DOI :
10.1109/NSSMIC.2012.6551714