• DocumentCode
    255880
  • Title

    Effects of leakage inductances on magnetically-coupled impedance-source networks

  • Author

    Siwakoti, Yam P. ; Loh, Poh Chiang ; Blaabjerg, Frede ; Town, Graham E.

  • Author_Institution
    Dept. of Eng., Macquarie Univ., Macquarie, NSW, Australia
  • fYear
    2014
  • fDate
    26-28 Aug. 2014
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    Coupled inductors have lately been used with impedance-source networks for keeping their shoot-through times short, while providing higher voltage boosts. The parameter that is critical to the operation of such impedance network based converter with coupled inductors is the leakage inductances. However, the role of leakage inductances and its effect on the converter performance is often overlooked. This paper analyzes the effects of leakage inductances and demonstrates experimentally how the presence of leakage inductances degrades the performance of the converter.
  • Keywords
    inductance; inductors; power convertors; coupled inductors; impedance-source networks; leakage inductances; magnetically-coupled impedance-source networks; power converter; Bridge circuits; Educational institutions; Equivalent circuits; Impedance; Inductors; Switches; Windings; G-Z-Source; Impedance Source Network; LCCT-Z-Source; Leakage Inductance; T-Source; TZ-Source; Trans-Z-Source; Y-Source;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
  • Conference_Location
    Lappeenranta
  • Type

    conf

  • DOI
    10.1109/EPE.2014.6910982
  • Filename
    6910982