DocumentCode
2559268
Title
A new kind of flow meter and flow controller based on weight-loss rate
Author
Wang, Shoujun ; Changsheng Ai ; Zhang, Hui ; Sun, Zuan ; Guoping
Author_Institution
Sch. of Mech. Eng., Jinan Univ., Jinan
fYear
2008
fDate
2-4 July 2008
Firstpage
1783
Lastpage
1786
Abstract
To solve the Cl2 flow control problem in PVC production process, a new kind of flow meter and flow controller is designed. The system is based on weight-loss rate method which used variation of the weight in a period of time for flow measurement. Single-chip microcomputer is used for the core of the control system, and dual integral A/D converter module for improving the resolving power and stability, hardware filter and Kalman theoretical digital filter is used to improve the signal-to-noise ratio. The systempsilas installation, working principle, and the hardware and software design are presented in detail. The system has an intelligent algorithm, high reliability and accuracy. It is easy to be installed and applied to the existing equipment.
Keywords
AC-DC power convertors; Kalman filters; chlorine; digital filters; flow control; flow measurement; flowmeters; plastics industry; process control; reliability; Kalman theoretical digital filter; PVC production process; dual integral A/D converter; flow controller; flow meter; hardware filter; signal-to-noise ratio; single-chip microcomputer; weight-loss rate; Control systems; Digital filters; Fluid flow measurement; Hardware; Microcomputers; Production; Signal resolution; Stability; Time measurement; Weight control; Dual integral A/D converter; Kalman filter; Single-chip microcomputer; flow controller; weight-loss method;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Decision Conference, 2008. CCDC 2008. Chinese
Conference_Location
Yantai, Shandong
Print_ISBN
978-1-4244-1733-9
Electronic_ISBN
978-1-4244-1734-6
Type
conf
DOI
10.1109/CCDC.2008.4597629
Filename
4597629
Link To Document