• DocumentCode
    2560783
  • Title

    Application of FastICA in on-line calibration of the current sensor´s phase difference

  • Author

    Gong Guoliang ; Lu Huaxiang

  • Author_Institution
    Neural Network Lab., Inst. of Semicond., Beijing, China
  • fYear
    2012
  • fDate
    29-31 May 2012
  • Firstpage
    330
  • Lastpage
    334
  • Abstract
    The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, a phase difference measurement method based on FastICA is proposed to calibrate the phase difference of the current sensor on-line. However, not all source components are mutually independent in our application. Additionally, due to limitations of the algorithm, the phase errors of the separated results are different in different test runs. In order to get an exact result, we have proposed an evaluation index to choose an optimal result from different runs. The index is based on the relationship of mapping components to observed signals. Simulation results indicate that the method presented in this paper is effective and feasible.
  • Keywords
    calibration; independent component analysis; phase measurement; sensors; FastICA; current sensor phase difference measurement method; evaluation index; independent component analysis; mapping components; online calibration; phase errors; power equipment; Accuracy; Dielectric loss measurement; Dielectric losses; Indexes; Signal to noise ratio; Independent Component Analysis (ICA); current sensor; dielectric loss; evaluation index; phase difference;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Natural Computation (ICNC), 2012 Eighth International Conference on
  • Conference_Location
    Chongqing
  • ISSN
    2157-9555
  • Print_ISBN
    978-1-4577-2130-4
  • Type

    conf

  • DOI
    10.1109/ICNC.2012.6234760
  • Filename
    6234760