• DocumentCode
    2560787
  • Title

    Many-view under-sampling (MVUS) technique for low-dose CT: Dose versus image quality

  • Author

    Taewon Lee ; Jonghwan Min ; Seungryong Cho

  • Author_Institution
    Korea Adv. Inst. of Sci. & Technol., Daejeon, South Korea
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    3617
  • Lastpage
    3619
  • Abstract
    In computed tomography (CT) imaging, radiation dose delivered to the patient is one of the major concerns. Among many technical solutions to lowering radiation dose while preserving clinical utilities of the images, sparse-view CT is a promising technique. However, a fast power switching of an x-ray tube, which is needed for the sparse-view sampling, can be challenging in many CT systems. We have recently proposed a novel alternative approach to sparse-view circular CT that can be readily incorporated in the existing CT systems, and have successfully shown its feasibility. Instead of switching the x-ray tube power, one can place an oscillating multi-slit collimator between the x-ray tube and the patient to partially block the x-ray beam thereby reducing the radiation. In this study, we performed a preliminary study on the effects of dose reduction via using multi-slit collimators of varying sizes of slit-openings on the reconstructed image quality. MicroCT projection data of a mouse were used and a numerical collimation was applied in the form of multi-slits. We used a sinusoidal motion of the collimator to the perpendicular direction of the rotation axis for the purpose of obtaining more uniform spatial sampling of the image. For image reconstruction, we used a total-variation minimization (TV) algorithm which has shown its out-performance in many sparse-view CT applications. This study UQI value was calculated to investigate the dependence of image quality on slit-opening size. Additionally, a visual image quality assessment was made.
  • Keywords
    collimators; computerised tomography; dosimetry; image reconstruction; image sampling; medical image processing; minimisation; numerical analysis; MVUS technique; TV minimization algorithm; UQI value; X-ray beam; X-ray tube power; computed tomography imaging; dose reduction effects; low-dose CT; many-view under-sampling technique; microCT projection data; numerical collimation; oscillating multislit collimator; perpendicular direction; radiation dose; reconstructed image quality; sinusoidal motion; slit-opening size; sparse-view circular CT; sparse-view sampling; spatial image sampling; total-variation minimization algorithm; universal quality index; visual image quality assessment;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551830
  • Filename
    6551830