DocumentCode
2560811
Title
A millimeter wave (18-40 GHz) coaxial and homodyne vector network analyzer
Author
Ghannouchi, F.M. ; Bosisio, R.G.
Author_Institution
Dept. of Electr. Eng., Ecole Polytech. de Montreal, Que., Canada
fYear
1990
fDate
11-14 June 1990
Firstpage
55
Lastpage
56
Abstract
An 18-40-GHz coaxial six-port reflectometer using four diode detectors is presented. The hardware configuration of the six-port junction as well as the linearization of diode detectors and the calibration of the six-port reflectometer are discussed. Absolute power measurements are not required during linearization of diode detectors. Comparison between experimental results obtained by both the six-port reflectometer and the Wiltron 360 Automatic Network Analyzer on a 3-dB attenuator terminated by a short circuit is presented. The reflectometer exhibits very good performance over the entire frequency band.<>
Keywords
calibration; linearisation techniques; microwave reflectometry; network analysers; reflectometers; 18 to 40 GHz; Wiltron 360 Automatic Network Analyzer; calibration; coaxial six-port reflectometer; four diode detectors; homodyne vector network analyzer; linearization; mm-wave; six-port junction; Attenuators; Bandwidth; Calibration; Coaxial components; Envelope detectors; Frequency; Millimeter wave measurements; Millimeter wave technology; Power measurement; Reflection;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
Conference_Location
Ottawa, Ontario, Canada
Type
conf
DOI
10.1109/CPEM.1990.109920
Filename
109920
Link To Document