DocumentCode
2560869
Title
AC-DC voltage transfer difference of the PTB-multijunction thermal converter at 1 MHz
Author
Klonz, M.
Author_Institution
Phys.-Tech. Bundesanstalt, Braunschweig, Germany
fYear
1990
fDate
11-14 June 1990
Firstpage
60
Lastpage
61
Abstract
The AC-DC voltage transfer difference of a 700- Omega -heater multijunction thermal converter has been evaluated in the frequency range from 100 kHz to 1 MHz using the same schematic diagram developed for frequencies below 100 kHz. The agreement between calculated and measured values with increasing transfer differences for lower heater resistances indicates the validity of the schematic diagram and the estimation procedure. The estimated uncertainty at 1 MHz is 10 p.p.m.<>
Keywords
convertors; voltage measurement; 100 kHz to 1 MHz; 700 ohm; AC-DC voltage transfer; PTB-multijunction thermal converter; international comparison; Analog-digital conversion; Connectors; Dielectric losses; Frequency conversion; Frequency estimation; Heat transfer; Standards publication; Uncertainty; Voltage; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
Conference_Location
Ottawa, Ontario, Canada
Type
conf
DOI
10.1109/CPEM.1990.109922
Filename
109922