DocumentCode
2560996
Title
The real time measuring of harmonic for three phase network
Author
Xu, Xin
Author_Institution
Beijing Electr. Power Sci. Res. Inst., China
fYear
1990
fDate
11-14 June 1990
Firstpage
77
Lastpage
78
Abstract
An instrument for real-time measurement of harmonic and negative-sequence components for three-phase networks is presented. The instrument has six separate analog measuring channels and microtransformers with electronic compensators and the signal prehandling circuits are used to minimize aliasing effects. The instrument uses a prestraightening sync-sample technique for leakage reduction and uses two monolithic microcomputers, as well as an arithmetic processor to enhance its analysis speed. It measures the magnitude and the phase of all harmonics up to the 60th as well as negative components of the fundamental voltage and current.<>
Keywords
computerised instrumentation; electric current measurement; electric distortion measurement; harmonic analysis; microcomputer applications; power system measurement; voltage measurement; aliasing effects; analogue measuring channels; electric distortion; electronic compensators; harmonics measurement; leakage reduction; microtransformers; monolithic microcomputers; negative-sequence components; phase; real-time measurement; signal prehandling circuits; sync-sample technique; three phase network; Circuits; Clocks; Current measurement; Harmonic analysis; Instruments; Phase measurement; Pollution measurement; Power measurement; Power system harmonics; Velocity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
Conference_Location
Ottawa, Ontario, Canada
Type
conf
DOI
10.1109/CPEM.1990.109930
Filename
109930