DocumentCode :
2561906
Title :
An international comparison of low audio frequency power meter calibrations conducted in 1989
Author :
Filipski, P.S. ; Moore, W.J.M. ; Knight, R.B.D. ; Martin, Patrick ; Oldham, N.M.
Author_Institution :
Nat. Res. Council, Ottawa, Ont., Canada
fYear :
1990
fDate :
11-14 June 1990
Firstpage :
158
Lastpage :
159
Abstract :
Summary form only given. The results of comparison of audio-frequency power meter calibrations conducted in 1989 between the National Research Council, Canada, the National Physical Laboratory, United Kingdom, and the National Institute of Standards and Technology, USA, are reported. A time-division watt converter, developed at the National Research Council, was used as the transfer standard. The measurements were made at 120 V, 5 A, power factors of one, zero lead and lag, and frequencies up to 5 kHz.<>
Keywords :
calibration; measurement standards; power measurement; wattmeters; 120 V; 5 A; 5 kHz; Canada; NIST; NPL; NRC; National Institute of Standards and Technology; National Physical Laboratory; National Research Council; United Kingdom; calibrations; international comparison; low audio frequency power meter; time-division watt converter; AC generators; Calibration; Frequency measurement; Instruments; Performance evaluation; Power measurement; Reactive power;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
Conference_Location :
Ottawa, Ontario, Canada
Type :
conf
DOI :
10.1109/CPEM.1990.109970
Filename :
109970
Link To Document :
بازگشت