Title : 
Experience with field coil interconnection failures on large hydro generators Part I
         
        
            Author : 
Bomben, S.G. ; LeBlanc, J.-B.
         
        
            Author_Institution : 
Ontario Power Generation, Niagara-on-the-Lake, ON, Canada
         
        
        
            fDate : 
May 31 2009-June 3 2009
         
        
        
        
            Abstract : 
Over the last several years, Ontario Power Generation has experienced multiple field coil interconnection failures on several different machines in the same power-house of the same manufacturer. There have been other instances of this type of failure at other powerhouses within OPG, all with the same common manufacturer. The rotor of a large hydro generator is often a forgotten component of the machine and at times, little effort is put into assessing the condition of this critical component other than a simple reactance test and a low voltage insulation resistance test. The paper will discuss the numerous failures experienced, site investigation, and the solution implemented for one of the stations.
         
        
            Keywords : 
hydroelectric generators; machine testing; field coil interconnection failures; hydro generators; Assembly; Coils; Dielectrics and electrical insulation; Insulation testing; Lead; Manufacturing; Power generation; Rotors; Solids; Synchronous generators;
         
        
        
        
            Conference_Titel : 
Electrical Insulation Conference, 2009. EIC 2009. IEEE
         
        
            Conference_Location : 
Montreal, QC
         
        
            Print_ISBN : 
978-1-4244-3915-7
         
        
            Electronic_ISBN : 
978-1-4244-3917-1
         
        
        
            DOI : 
10.1109/EIC.2009.5166391