Title : 
Comparison of DC Ramp and DC step tests results on hydro generator stators
         
        
            Author : 
Lamarre, Laurent ; David, Éric ; Nair, Amrish
         
        
            Author_Institution : 
Hydro-Quebec (IREQ), Varennes, QC, Canada
         
        
        
            fDate : 
May 31 2009-June 3 2009
         
        
        
        
            Abstract : 
This work aims at comparing results obtained from the DC Ramp test with the DC step test on the stator insulation of large hydro generators. Four cases of field measurements done on hydro generators are presented. Results are analyzed according to analytical solutions presented by the authors in recent publications for both methods. Quantities such as IR, PI, absorption current parameters and leakage currents are tabulated for each case and various aspects regarding respective advantages and complementarities pertaining to each method are discussed.
         
        
            Keywords : 
hydroelectric generators; insulation testing; leakage currents; DC ramp test; DC step test; field measurement; hydro generator stator; leakage current; stator insulation; Conducting materials; DC generators; Dielectrics and electrical insulation; Electromagnetic wave absorption; Insulation testing; Leakage current; Mechanical engineering; Polarization; Stators; Voltage;
         
        
        
        
            Conference_Titel : 
Electrical Insulation Conference, 2009. EIC 2009. IEEE
         
        
            Conference_Location : 
Montreal, QC
         
        
            Print_ISBN : 
978-1-4244-3915-7
         
        
            Electronic_ISBN : 
978-1-4244-3917-1
         
        
        
            DOI : 
10.1109/EIC.2009.5166392