• DocumentCode
    2566492
  • Title

    A 1V 2.3/spl mu/W Biomedical Signal Acquisition IC

  • Author

    Honglei Wu ; Yong Ping Xu

  • Author_Institution
    Singapore Nat. Univ.
  • fYear
    2006
  • fDate
    6-9 Feb. 2006
  • Firstpage
    119
  • Lastpage
    128
  • Abstract
    A 1V 2.3uW biomedical signal acquisition IC is fabricated in a 0.35muum CMOS process. It consists of an LIMA and an 11b ADC. The OTA achieves an optimum trade-off between noise and power consumption with rail-to-rail output. A pseudo-S/H circuit is incorporated in the OTA. The modified successive-approximation ADC allows rail-to-rail inputs
  • Keywords
    CMOS integrated circuits; analogue-digital conversion; biomedical electronics; operational amplifiers; sample and hold circuits; 0.35 micron; 1 V; 2.3 muW; ADC; CMOS process; LIMA; OTA; biomedical signal acquisition IC; pseudo S/H circuit; Batteries; Biomedical monitoring; Capacitors; Circuit noise; Integrated circuit noise; Noise measurement; Noise reduction; Patient monitoring; Signal to noise ratio; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid-State Circuits Conference, 2006. ISSCC 2006. Digest of Technical Papers. IEEE International
  • Conference_Location
    San Francisco, CA
  • ISSN
    0193-6530
  • Print_ISBN
    1-4244-0079-1
  • Type

    conf

  • DOI
    10.1109/ISSCC.2006.1696040
  • Filename
    1696040