DocumentCode
2570889
Title
Fast single molecule localization using graphics processing units
Author
Lidke, Keith A.
Author_Institution
Dept. of Phys. & Astron., Univ. of New Mexico, Albuquerque, NM, USA
fYear
2012
fDate
2-5 May 2012
Firstpage
919
Lastpage
920
Abstract
We demonstrate maximum likelihood estimations of fluorophore positions in 2D and 3D using algorithms optimized for or accelerated by graphical processing units. The result is a reduction in computation time by two orders of magnitude.
Keywords
biology computing; fluorescence; graphics processing units; maximum likelihood estimation; molecular biophysics; optimisation; fast single molecule localization; fluorescence; fluorophore 2D positions; fluorophore 3D positions; graphics processing units; maximum likelihood estimations; optimized algorithms; Fitting; Fluorescence; Graphics processing unit; Hardware; Imaging; Maximum likelihood estimation; fluorescence; super-resolution;