DocumentCode :
2571322
Title :
In-vitro assessment of the effects of cellular phones on implantable cardioverter defibrillator (ICD) function
Author :
Carey, Carole C. ; Ruggera, Paul S.
Author_Institution :
Center for Devices & Radiol. Health, US Food & Drug Adm., Rockville, MD, USA
Volume :
6
fYear :
1998
fDate :
29 Oct-1 Nov 1998
Firstpage :
3303
Abstract :
The design of cardiac pulse generators has evolved from an artificial pacemaker single therapy device to a multifunctional therapeutic device known as an implantable cardioverter defibrillator and pacemaker. Composed of complex digital circuitry and discrete components, these devices may exhibit susceptibility to EMI. Despite shielding the internal mechanism of pacemakers and ICDs with titanium casing and using improved noise filtering techniques, new sources of EMI continue to pose challenges in EMC design of these devices. There have been previous reports of interference from RF sources such as radar transmitters, hand-held radios, and anti-theft devices. More recently, with the proliferation of wireless communication, reports of interference by digital cellular telephones have also surfaced. FDA/CDRH initiated an examination of the potential for cellular telephones to interfere with implanted pacemakers in 1995. Results of these evaluations led CDRH engineers to investigate the potential EMI effects of these telephones to ICD function. The investigation involved ICDs from six manufacturers versus four types of digital cellular telephones. An RF powered dipole antenna was also used to evaluate it as an alternative RF source for EMI testing
Keywords :
cellular radio; defibrillators; electromagnetic compatibility; pacemakers; radiofrequency interference; EMC design; EMI susceptibility; RF powered dipole antenna; cardiac pulse generators; cellular phones effect; device immunity; digital cellular telephones; human torso simulator; implantable cardioverter defibrillator function; implanted pacemakers; in-vitro assessment; Cardiology; Cellular phones; Circuits; Electromagnetic interference; In vitro; Medical treatment; Pacemakers; Pulse generation; Radio frequency; Telephony;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1998. Proceedings of the 20th Annual International Conference of the IEEE
Conference_Location :
Hong Kong
ISSN :
1094-687X
Print_ISBN :
0-7803-5164-9
Type :
conf
DOI :
10.1109/IEMBS.1998.746205
Filename :
746205
Link To Document :
بازگشت