DocumentCode :
2571885
Title :
Robust sensor fault detection and isolation for a doubly-fed induction generator
Author :
Boulkroune, B. ; Gálvez-Carrillo, M. ; Kinnaert, M.
Author_Institution :
Dept. of Control Eng. & Syst. Anal., Univ. Libre de Bruxelles (ULB), Brussels, Belgium
fYear :
2010
fDate :
15-17 Dec. 2010
Firstpage :
1600
Lastpage :
1606
Abstract :
The problem of multiplicative fault detection and isolation (FDI) in the current sensors of a doubly-fed induction generator (DFIG) is considered in the presence of model uncertainty. A residual generator based on the DFIG model is proposed using the structure of the classical generalized observer scheme (GOS). However, each observer in this scheme is replaced by a robust H-/H fault detection filter followed by a Kalman-like observer. It turns out that the fault detection/isolation problem then amounts to detecting the appearance of sine waves superimposed to specific components of a white noise vector. A Generalized Likelihood Ratio Test (GLRT) is developed to solve the problem. The complete FDI system is validated through simulations on a controlled DFIG.
Keywords :
H control; asynchronous generators; fault diagnosis; machine control; observers; white noise; DFIG model; Kalman like observer; classical generalized observer; complete FDI system; current sensors; doubly-fed induction generator; generalized likelihood ratio test; model uncertainty; residual generator; robust H-/H fault detection filter; robust sensor fault detection; robust sensor fault isolation; white noise vector; Fault detection; Observers; Robustness; Rotors; Stator windings; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Decision and Control (CDC), 2010 49th IEEE Conference on
Conference_Location :
Atlanta, GA
ISSN :
0743-1546
Print_ISBN :
978-1-4244-7745-6
Type :
conf
DOI :
10.1109/CDC.2010.5717380
Filename :
5717380
Link To Document :
بازگشت