• DocumentCode
    2572832
  • Title

    Experimental Studies of Multi-Wire Arrays on the Cobra Generator

  • Author

    McBride, R.D. ; Douglass, J.D. ; Pikuz, S.A. ; Shelkovenko, T.A. ; Greenly, J.B. ; Hammer, D.A. ; Kusse, B.R.

  • Author_Institution
    Lab. of Plasma Studies, Cornell Univ., Ithaca, NY
  • fYear
    2005
  • fDate
    20-23 June 2005
  • Firstpage
    307
  • Lastpage
    307
  • Abstract
    Summary form only given. The rebuilt pulsed power generator, COBRA, capable of providing variable current pulses (e.g., 0.6-1 MA peak current; 100-150 ns rise times), is currently being used to study wire array Z-pinch implosions at Cornell University. Wire arrays constructed from four, eight, and twelve wires of aluminum, nickel, tungsten, Invar (Fe, Ni alloy), as well as other materials, have been tested. Various array diameters have also been tested, although typically 1.6 cm has been used, and the standard array height is 20 mm. The influence of the current waveform on the array implosion has been studied using X-ray imaging diagnostics with spatial and/or temporal resolution. Photodiodes such as XRD, PCD, and AXUV-HS were used with various filters to investigate a wide energy range that spanned from EUV up to 10-keV X-rays during various stages of the array implosion process. Characteristic to this research was the use of X-ray backlighting, which was employed to focus in on the explosion processes of the individual wires during an array implosion. The source of the X-ray backlighting was two, four-wire X pinches made from either aluminum or molybdenum wires. These X pinches replaced two of the four standard electron return current posts in the anode hardware setup, and were capable of providing the desired point-projection backlighting. This imaging technique made it possible to determine the expansion rates and inner structure of the various wire cores, as well as to observe the development of sausage instabilities. Additionally, a spherically bent mica crystal spectrograph and a flat KAP crystal spectrograph were used to determine plasma parameters for both the X pinches and the main wire array. Pinhole cameras were also used, and provided wide view images of the entire configuration. The images consist of a full view of the main array, with an X pinch off to either side. By using various filters with these pinhole cameras, potential problems associated wit- the wire contacts at the electrodes were observed. These observations have been examined to understand the influence of contact points on precursor plasma formation
  • Keywords
    Invar; Z pinch; aluminium; exploding wires; explosions; nickel; plasma X-ray sources; plasma diagnostics; plasma transport processes; sausage instability; tungsten; 0.6 to 1 MA; 100 to 150 ns; AXUV-HS; Al; COBRA generator; FeNi; Ni; PCD; W; X pinches; X-ray backlighting; X-ray imaging diagnostics; XRD; anode hardware; current waveform; electron return current posts; flat KAP crystal spectrograph; photodiodes; pinhole cameras; point-projection backlighting; precursor plasma formation; pulsed power generator; sausage instabilities; spherically bent mica crystal spectrograph; wire array Z-pinch implosions; Aluminum; Cameras; Filters; Nickel; Plasmas; Power generation; Pulse generation; Tungsten; Wire; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2005. ICOPS '05. IEEE Conference Record - Abstracts. IEEE International Conference on
  • Conference_Location
    Monterey, CA
  • ISSN
    0730-9244
  • Print_ISBN
    0-7803-9300-7
  • Type

    conf

  • DOI
    10.1109/PLASMA.2005.359429
  • Filename
    4198688