• DocumentCode
    2573205
  • Title

    Characterization of emphysema in low dose computed tomography images using maximum likelihood estimation of the scale exponent

  • Author

    Ceresa, Mario ; Muñoz-Barrutia, Arrate ; Ortiz-de-Solórzano, Carlos

  • Author_Institution
    Center for Appl. Med. Res. (CIMA), Univ. of Navarra, Pamplona, Spain
  • fYear
    2012
  • fDate
    2-5 May 2012
  • Firstpage
    1447
  • Lastpage
    1450
  • Abstract
    Low attenuation clusters (LACs) are associated with the presence of emphysema in low dose computer tomography (LDCT) scans. It is believed that the LACs´ frequency-size distribution can be appropriately fit with power law and be well described with the scale exponent. In this work, we investigated whether the LACs´ frequency-size distribution of a group of 80 LDCT scans taken from a lung cancer-screening program followed a power-law behavior. Contrary to the current thinking, only a subset of the data (60%) actually allowed a power-law fit. This suggests that the claims of power-law behavior in LAC´s frequency-size distribution is a delicate issue and should be regarded with care.
  • Keywords
    cancer; computerised tomography; lung; maximum likelihood estimation; medical image processing; emphysema characterization; frequency-size distribution; low attenuation clusters; low-dose computed tomography images; lung cancer-screening program; maximum likelihood estimation; power-law behavior; scale exponent; Cancer; Computed tomography; Diseases; Lungs; Maximum likelihood estimation; USA Councils; COPD; Emphysema quantification; low dose computer tomography images; power-law; scaling exponent;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging (ISBI), 2012 9th IEEE International Symposium on
  • Conference_Location
    Barcelona
  • ISSN
    1945-7928
  • Print_ISBN
    978-1-4577-1857-1
  • Type

    conf

  • DOI
    10.1109/ISBI.2012.6235843
  • Filename