Abstract :
Various ageing processes that occur in organic insulators when they are exposed to the weather are investigated. The operating conditions (rain, contamination,UV radiation, etc.) are related to the physical damage that they produce and the electrical or mechanical failure which may finally occur. Laboratory tests of material samples and pin-type insulator prototypes are reported. Results obtained for a 15-kV insulator (NEMA 55.4) are satisfactory.<>
Keywords :
ageing; environmental testing; failure analysis; insulation testing; organic insulating materials; 15 kV; NEMA 55.4; UV radiation; ageing processes; contamination; electrical failure; laboratory tests; mechanical failure; organic insulators; physical damage; pin-type insulator prototypes; rain; synthetic insulators; weather exposure; Building materials; Degradation; Dielectrics and electrical insulation; Failure analysis; Feedback; Insulation life; Insulator testing; Materials testing; Polymers; Surface discharges;