• DocumentCode
    2574044
  • Title

    Topology discovery in PROFINET

  • Author

    Schafer, Iwan ; Felser, Max

  • Author_Institution
    Berne Univ. of Appl. Sci., Burgdorf
  • fYear
    2007
  • fDate
    25-28 Sept. 2007
  • Firstpage
    704
  • Lastpage
    707
  • Abstract
    PROFINET, an automation network based on Ethernet, includes the automatic discovery of the physical topology with the link layer discovery protocol (LLDP) in its newest specifications. In this paper we present the objectives of LLDP in PROFINET and general information about the protocol and other parts of IEEE 802.1AB, which describes LLDP. During the analysis of different implementations on the market, we found several problems of LLDP as well as issues with the interaction to a network management system. These are described in the later chapters.
  • Keywords
    computer network management; local area networks; protocols; telecommunication network topology; Ethernet; IEEE 802.1AB; PROFINET; automation network; link layer discovery protocol; network management system; physical topology discovery; Automation; Computer network management; Delay effects; Ethernet networks; Field buses; IEC standards; Network topology; Protocols; Switches; Telecommunication traffic;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Emerging Technologies and Factory Automation, 2007. ETFA. IEEE Conference on
  • Conference_Location
    Patras
  • Print_ISBN
    978-1-4244-0825-2
  • Electronic_ISBN
    978-1-4244-0826-9
  • Type

    conf

  • DOI
    10.1109/EFTA.2007.4416837
  • Filename
    4416837