Closed-loop MIMO ARX estimation of concurrent external plasma response eigenmodes in magnetic confinement fusion
Author
Olofsson, Erik ; Rojas, Cristian R. ; Hjalmarsson, Håkan ; Brunsell, Per ; Drake, James R.
Author_Institution
Sch. of Electr. Eng. (EES), R. Inst. of Technol. (KTH), Stockholm, Sweden
fYear
2010
fDate
15-17 Dec. 2010
Firstpage
2954
Lastpage
2959
Abstract
Detailed experimental MIMO models of plasma stability behaviour are becoming increasingly important in magnetic confinement fusion (MCF) energy research as an assortment of magnetohydrodynamic (MHD) instabilities develop when fusion performance is pushed. Some of these problems could perhaps be handled by magnetic feedback. We here show a practical method for experimental closed-loop multi-input multi-output (MIMO) characterisation of the macroscopic stability of toroidal MCF devices. It is demonstrated, by application to the MCF experiment EXTRAP T2R, that MHD eigenmodes can be detected using the workhorse MIMO autoregressive exogeneous (ARX) model structure. Plausibly, the presented methodology could significantly improve highly-desired magnetic feedback accuracy in MCF.
Keywords
MIMO systems; autoregressive processes; closed loop systems; control engineering computing; feedback; magnetic variables control; physics computing; plasma instability; plasma magnetohydrodynamics; reversed field pinch; signal processing; EXTRAP T2R experiment; MHD eigenmodes; autoregressive exogeneous model; closed-loop MIMO ARX estimation; closed-loop multi-input multi-output characterisation; concurrent external plasma response eigenmodes; magnetic confinement fusion; magnetic feedback; magnetohydrodynamic instabilities; toroidal MCF device macroscopic stability; versed-field pinch; Coils; MIMO; Magnetic resonance; Magnetohydrodynamics; Tokamaks; Toroidal magnetic fields;
fLanguage
English
Publisher
ieee
Conference_Titel
Decision and Control (CDC), 2010 49th IEEE Conference on
Conference_Location
Atlanta, GA
ISSN
0743-1546
Print_ISBN
978-1-4244-7745-6
Type
conf
DOI
10.1109/CDC.2010.5717656