• DocumentCode
    2578307
  • Title

    Keep the lamps down low

  • Author

    Benz, Glen E.

  • Author_Institution
    Teledyne Controls, Los Angeles, CA, USA
  • fYear
    1991
  • fDate
    29-31 Jan 1991
  • Firstpage
    98
  • Lastpage
    100
  • Abstract
    An estimation of maintenance rates for contemporary illuminated panels involves a number of problems and alternative policies. Voltage stress derating can be used to extend the life of redundant lamp pairs such that it exceeds total usage time in the end item. Keeping the lamps down low can produce large reductions in life cycle costs
  • Keywords
    lamps; maintenance engineering; illuminated panels; life extension; maintenance rates; redundant lamp pairs; voltage stress derating; Hydrogen; Lamps; Maintenance; Manufacturing; Stress; Sun; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability and Maintainability Symposium, 1991. Proceedings., Annual
  • Conference_Location
    Orlando, FL
  • Print_ISBN
    0-87942-661-6
  • Type

    conf

  • DOI
    10.1109/ARMS.1991.154421
  • Filename
    154421