Title :
Additional application fields of a modern wind generator even at no-wind
Author :
Schmidt, István ; Veszprémi, Károly
Author_Institution :
Budapest Univ. of Technol. & Econ., Budapest
Abstract :
A modern variable speed wind turbine generator is connected to the lines (grid) through a both sides PWM controlled DC link voltage source inverter. The fast current control of the line currents by the line-side converter makes possible to compensate the deviation of the line currents from their fundamental component. This possibility can be used to compensate the lower order current harmonics in the line currents (injected by nonlinear loads on the lines) and to balance the negative sequence current component (caused by asymmetrical load). Besides, advanced control strategies make possible to control the reactive (and also the active) power of the lines, resulting in power factor correction. Since all the mentioned subjects of compensations require at most pulsating active power with zero mean value, the listed compensations are possible even at no-wind condition. Of course, the pulsating active power affects the pulsation of the dc link voltage, the limits of the compensations in this sense must be investigated. All the investigated additional application fields improve the power quality of lines (grid) where the wind turbine generator is connected to. The practical aim of this paper is to attract the attention of the wind turbine makers to these additional application fields. The paper presents the advanced possible line-side converter control schemes. The physical and theoretical background of the different compensations are discussed. The issues of their implementation by the presented control methods are detailed. The methods are investigated and validated by simulations of practical examples. Design criteria are given based on the considerations.
Keywords :
PWM invertors; electric current control; machine vector control; power factor correction; power generation control; power system harmonics; reactive power control; turbogenerators; wind power plants; PWM controlled DC link voltage source inverter; active power pulsation; asymmetrical load; current harmonics; current vector control; line-side converter control; negative sequence current component; no-wind condition; nonlinear loads; power factor correction; power quality; reactive power control; variable speed wind turbine generator; Current control; DC generators; Mesh generation; Power factor correction; Power generation; Power quality; Pulse width modulation inverters; Voltage control; Wind energy generation; Wind turbines; Active filter; Direct power control; Power Quality; Power factor correction; Pulse Width Modulation (PWM); Renewable energy systems; Vector control; Voltage Source Inverters (VSI);
Conference_Titel :
Power Electronics and Applications, 2007 European Conference on
Conference_Location :
Aalborg
Print_ISBN :
978-92-75815-10-8
Electronic_ISBN :
978-92-75815-10-8
DOI :
10.1109/EPE.2007.4417206