Abstract :
In interleaved converters, the commutation cells can be interconnected by intercell transformers. In this paper we show how a modified sequence of the voltages applied to windings reduces the flux density in the magnetic core branches. Experimental measurements confirm the flux reduction obtained with the modified supply. Thermal measurements were made in order to evaluate the reduction of total core losses when the modified supply is used.
Keywords :
commutation; loss measurement; power convertors; transformer cores; transformer windings; commutation cells; core losses measurements; flux density; intercell transformers; interleaved converters; thermal measurements; Core loss; Inductors; Loss measurement; Magnetic cores; Magnetic flux; Magnetic separation; Plasma measurements; Topology; Transformers; Uniform resource locators; Interleaved converters; Measurement; Standard; Transformer;