DocumentCode
2579933
Title
A redundant electrical braking system for wind turbine generators
Author
Wang, Timothy CY ; Yang, Wenqiang ; Yuan, Xiaoming ; Teichmann, Ralph
Author_Institution
GE Global Res. Center, Shanghai
fYear
2007
fDate
2-5 Sept. 2007
Firstpage
1
Lastpage
8
Abstract
Mechanical brake is typically used in wind turbine, which typically suffers from frequent wear-out, more trip opportunities and high maintenance cost. To addressing this issue, a redundant electrical braking system is proposed in this paper. It comprises a conventional dynamic brake connected to the converter DC link and a fully controllable resistive load connected to the generator terminals. The resistive load can be engaged by an active power semiconductor and a NC(normally closed) contactor.
Keywords
braking; contactors; power semiconductor devices; turbogenerators; wind turbines; active power semiconductor; converter DC link; dynamic brake; electrical braking system; fully controllable resistive load; generator terminals; mechanical brake; normally closed contactor; wind turbine generators; Contacts; Costs; DC generators; Hybrid power systems; Mesh generation; Power system dynamics; Resistors; Torque control; Wind energy generation; Wind turbines; Electrical braking; crow bar; dump load; wind turbine;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications, 2007 European Conference on
Conference_Location
Aalborg
Print_ISBN
978-92-75815-10-8
Electronic_ISBN
978-92-75815-10-8
Type
conf
DOI
10.1109/EPE.2007.4417293
Filename
4417293
Link To Document