DocumentCode :
2581587
Title :
An alternative method for preparing FMECA´s
Author :
Sexton, Ronald D.
Author_Institution :
BAe. plc, Bristol, UK
fYear :
1991
fDate :
29-31 Jan 1991
Firstpage :
222
Lastpage :
225
Abstract :
Some of the practical problems associated with the application of formal, MIL-STD-1629, failure modes and effects analyses (FMEAs) are addressed, and an alternative cost-saving methodology is proposed. The technique is fast in application and allows engineers to influence design decisions, using FMEA studies, as the design progresses. The technique follows the spirit of the standard, rather than its letter, and overcomes what is considered one of the major shortcomings of the standard, since a single failure can effectively only disrupt one system function. It is noted that the methods described have already rapidly gained acceptance and wide application in the United Kingdom
Keywords :
design engineering; failure analysis; reliability; FMEA; FMECA; MIL-STD-1629; UK; design; failure modes and effects analyses; military systems; reliability; standards; Aerodynamics; Application software; Costs; Design engineering; Failure analysis; Filling; Military standards; Process design; Programmable control; Reliability engineering;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Reliability and Maintainability Symposium, 1991. Proceedings., Annual
Conference_Location :
Orlando, FL
Print_ISBN :
0-87942-661-6
Type :
conf
DOI :
10.1109/ARMS.1991.154439
Filename :
154439
Link To Document :
بازگشت