    Sweep linearization of a microwave FMCW Doppler sensor by an ultrasonic reference

  • Author

    Ruser, H. ; Mágori, V.

  • Author_Institution
    Corp. Technol., Siemens AG, Munich, Germany
  • fYear
    1997
  • fDate
    28-30 May 1997
  • Firstpage
    201
  • Lastpage
    206
  • Abstract
    For a microwave FMCW Doppler sensor, a new linearization method is proposed using an ultrasonic FM reference signal. The received microwave signal is sampled with a sampling interval adapted to the phase intervals of the ultrasonic reference signal. With this linearized combined microwave/ultrasonic FMCW Doppler sensor, additionally to a high target detection reliability, a significantly improved resolution for range and velocity measurements and good multi-target selectivity are achieved
  • Keywords
    Doppler measurement; computerised instrumentation; linearisation techniques; microwave measurement; sensors; signal sampling; ultrasonic measurement; velocity measurement; frequency modulated continuous wave sensor; high target detection reliability; linearized combined microwave/ultrasonic Doppler sensor; microwave Doppler sensor; multi-target selectivity; range measurements; received microwave signal; resolution; sampling interval; sweep linearization; ultrasonic FM reference signal; ultrasonic reference; ultrasonic reference signal; velocity measurements; Continuous phase modulation; Delay effects; Frequency modulation; Linearity; Microwave sensors; Microwave theory and techniques; Object detection; Sampling methods; Signal resolution; Velocity measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium, 1997., Proceedings of the 1997 IEEE International
  • Conference_Location
    Orlando, FL
  • Print_ISBN
    0-7803-3728-X
  • Type

    conf

  • DOI
    10.1109/FREQ.1997.638544
  • Filename
    638544