• DocumentCode
    2585185
  • Title

    Implementation and laboratory test results of an Elman network-based transmission line directional relay

  • Author

    Sanaye-Pasand, M. ; Malik, O.P.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Tehran Univ., Iran
  • Volume
    2
  • fYear
    1999
  • fDate
    31 Jan-4 Feb 1999
  • Abstract
    Summary form only as given. A transmission line fault direction identification module based on an Elman recurrent network has been implemented on a DSP board and its behaviour is investigated on a physical power system model. Details of implementation and the experimental studies ore given and analysed in the paper. Studies show that the proposed approach is able to identify the direction of a fault on a transmission line rapidly and correctly. It is suitable to realize a fast transmission line directional fault locator.
  • Keywords
    fault location; power system analysis computing; power transmission faults; power transmission lines; recurrent neural nets; DSP board; Elman recurrent network; computer simulation; fault direction; power system; transmission line fault direction identification module; Digital signal processing; Fault diagnosis; Laboratories; Power system analysis computing; Power system modeling; Power system relaying; Power transmission lines; Relays; Testing; Transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Society 1999 Winter Meeting, IEEE
  • Print_ISBN
    0-7803-4893-1
  • Type

    conf

  • DOI
    10.1109/PESW.1999.747304
  • Filename
    747304