• DocumentCode
    2586031
  • Title

    Comparative thermodynamic analysis of energy systems for power recovery from industrial low heat sources

  • Author

    Ling, Z.G. ; Deng, X.Y.

  • Author_Institution
    Shanghai Univ. of Eng. Sci., China
  • fYear
    1989
  • fDate
    6-11 Aug 1989
  • Firstpage
    1941
  • Abstract
    A comparative thermodynamic analysis of energy systems for power recovery from industrial low-heat sources has been made among flashing expansion, organic Rankine cycle (ORC), total-flow, total-flow-with-separation, and combined systems. The results show that single and two-stage flashing systems are special cases of total-flow separation systems. The latter is more efficient than an ORC system from 80°C and is better for higher temperatures. Regression formulas for predicting power recovery for total-flow separation systems are given for practical use
  • Keywords
    heat engines; thermodynamics; energy systems; flashing expansion; industrial low heat sources; organic Rankine cycle; power recovery; regression formulas; thermodynamic analysis; total-flow; total-flow-with-separation; Cogeneration; Heat pumps; Heat recovery; Potential energy; Power system reliability; Temperature; Thermodynamics; Waste heat; Water heating; Water resources;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Engineering Conference, 1989. IECEC-89., Proceedings of the 24th Intersociety
  • Conference_Location
    Washington, DC
  • Type

    conf

  • DOI
    10.1109/IECEC.1989.74737
  • Filename
    74737