Title : 
Traceability of frequency control systems
         
        
            Author : 
Boulanger, J.-S. ; Douglas, R.J.
         
        
            Author_Institution : 
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
         
        
        
        
        
        
            Abstract : 
Traceability of frequency transfers in frequency control systems needs to be unambiguously defined and measured. Until now the Allan deviation has been used as a good approximation because exact calculation seemed to be beyond practicality. With the help of the A-B structure factors, which we developed [1], it is almost trivial to link the standard uncertainty in frequency transfer to the Allan deviation in an easy and unambiguous way, answering the need for compliance to a formal definition of traceability frequency transfer
         
        
            Keywords : 
Global Positioning System; frequency control; frequency stability; measurement errors; measurement standards; oscillators; random noise; A-B structure factors; Allan deviation; GPS; frequency control systems; measurement errors; measurement standards; oscillators; standard uncertainty; traceability frequency transfer; Councils; Frequency control; Frequency estimation; Frequency measurement; Measurement standards; Measurement uncertainty; Noise measurement; Standards development; Time measurement; White noise;
         
        
        
        
            Conference_Titel : 
Frequency Control Symposium, 1997., Proceedings of the 1997 IEEE International
         
        
            Conference_Location : 
Orlando, FL
         
        
            Print_ISBN : 
0-7803-3728-X
         
        
        
            DOI : 
10.1109/FREQ.1997.638569