DocumentCode :
25893
Title :
A Fast Readout Electronic System for Accurate Spatial Detection in Ion Beam Tracking for the Next Generation of Particle Accelerators
Author :
Garzon-Camacho, Alejandro ; Fernandez, B. ; Alvarez, Marcos A. G. ; Ceballos, Joaquin ; de la Rosa, Jos M.
Author_Institution :
Inst. for the Struct. of Matter, Madrid, Spain
Volume :
64
Issue :
2
fYear :
2015
fDate :
Feb. 2015
Firstpage :
318
Lastpage :
327
Abstract :
This paper presents the design, implementation, and measurements of a complete electronic frontend intended for high-resolution spatial detection of ion beams at counting rates higher than 106 particles per second (p/s). The readout system is made up of three main multichannel building blocks, namely, a transimpedance preamplifier, a signal-conditioning line receiver, and a charge-to-digital converter, as well as some off-the-shelf components. The preamplifier and the line receiver have been specifically designed and optimized to minimize the overlapping probability of ion beams tracking, at high counting rates, in low-pressure gaseous secondary electron detectors. Experimental results are shown, considering α particles sources and particles beams, featuring an adaptive shaping time frame of 170-230 ns with a peak signal-to-noise ratio of up to 25 dB. These performance metrics are competitive with the state of the art, demonstrating the suitability of the reported data acquisition and instrumentation system for precise and fast particle tracking detection.
Keywords :
data acquisition; electron detection; ion beam applications; operational amplifiers; particle accelerators; particle beams; particle sources; preamplifiers; probability; readout electronics; signal conditioning circuits; adaptive shaping time frame; charge-to-digital converter; complete electronic frontend measurement; data acquisition; fast readout electronic system; high-resolution spatial detection; instrumentation system; ion beam tracking; line receiver; low-pressure gaseous secondary electron detector; multichannel building block; overlapping probability line; particle accelerator; particle beam; particle tracking detection; particles source; signal-conditioning line receiver; time 170 ns to 230 ns; transimpedance preamplifier; Cathodes; Detectors; Integrated circuit modeling; Ion beams; Readout electronics; Receivers; Detectors; particle tracking; radioactive ions beams (RIBs); readout electronics; spatial detection;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2014.2344351
Filename :
6877719
Link To Document :
بازگشت