DocumentCode :
2589332
Title :
Cement plant preheater fan build-up control
Author :
Cohen, S.M.
fYear :
1990
fDate :
22-24 May 1990
Firstpage :
101
Lastpage :
113
Abstract :
All outline is given of two different approaches used to study the problem of kiln induced draft (ID) fan buildup problems. These are: (1) a study based on information from as many plants as possible to see if a pattern of buildup can be related to plant operating parameters and or raw material composition; (2) a laboratory study in which process operating conditions of the kiln ID fan were set up on a small scale to determine if the buildup problem seem in the field could be duplicated, and, if so, how could it be eliminated. Theories as to primary causes for the buildup have been divided into four primary groups: thermal, clinical, electrostatic and mechanical. All are discussed. Results of laboratory test work are outlined
Keywords :
cement industry; cement plant; clinical properties; electrostatic properties; kiln induced draft; mechanical properties; plant operating parameters; preheater fan build-up control; raw material composition; thermal properties; Costs; Fans; Ferroelectric films; Gases; Impellers; Kilns; Nonvolatile memory; Random access memory; Springs; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Cement Industry Technical Conference, 1990., XXXII, Record of Conference Papers., IEEE
Conference_Location :
Tarpon Springs, FL
ISSN :
1079-9931
Type :
conf
DOI :
10.1109/CITCON.1990.111050
Filename :
111050
Link To Document :
بازگشت