DocumentCode :
2591951
Title :
Turbogenerator units operating on duo-flash cycle in the Yangbajain geothermal power plant, Tibet, China
Author :
Shanben, Qian ; Fangxun, L.I. ; Nianru, L.I.
Author_Institution :
Qingdao Steam Turbine Works, Shantong, China
fYear :
1989
fDate :
6-11 Aug 1989
Firstpage :
2151
Abstract :
Three 3000-kW geothermal turbogenerator units that have been in successful commercial operation since 1981 in Tibet are discussed. Because of shortage of conventional energy in that region, a double-flash-cycle system was chosen to obtain maximal electrical output. The design features of the units and operational experience with them are described. Suggestions for their optimization are given
Keywords :
geothermal power stations; turbogenerators; 3000 kW; China; Tibet; Yangbajain; design features; double-flash-cycle system; electrical output; geothermal power plant; operational experience; optimization; turbogenerator units; Fossil fuels; Geothermal energy; Geothermal power generation; Power generation; Power supplies; Power system modeling; Sea level; Turbines; Turbogenerators; Valves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Engineering Conference, 1989. IECEC-89., Proceedings of the 24th Intersociety
Conference_Location :
Washington, DC
Type :
conf