Abstract
After a detailed study of recoverable materials in heat exchangers included in a post-use air conditioner, an efficient separating method has been developed to recover copper and aluminum, which are component materials of the heat exchangers. In this separating method, the heat exchangers are treated by a rolling machine to enhance the separability with utilizing the difference of mechanical characteristics between copper and aluminum, and then the products are crushed, separated and classified to recover high quality copper and aluminum. This separating method has made it possible to recover copper and aluminum of more than 95% quality from the heat exchangers
Keywords
air conditioning; aluminium; copper; heat exchangers; recycling; Al; Cu; heat exchangers; metal recovery; post-use air conditioner; recoverable materials; recycling; rolling machine; separability; separation method; Aluminum; Copper; Heat recovery; Home appliances; International trade; Iron; Manufacturing; Recycling; Research and development; Shape;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmentally Conscious Design and Inverse Manufacturing, 1999. Proceedings. EcoDesign '99: First International Symposium On
Conference_Location
Tokyo
Print_ISBN
0-7695-0007-2
Type
conf
DOI
10.1109/ECODIM.1999.747723
Filename
747723
Link To Document