  • Abstract
    This paper presents the analysis of a current control system to PMSG in overmodulation region. A detailed review of the space vector modulation in over-modulation region is initially presented. Then, an anti-windup method for current controller of PMSG is proposed. The equilibrium points of the closed loop system are calculated and an estimation of the region of operation with guaranteed stability is determined using linear matrix inequalities. Simulation results are presented and illustrate suitable closed loop performance.
  • Keywords
    closed loop systems; electric current control; linear matrix inequalities; machine control; permanent magnet generators; stability; synchronous generators; anti-windup method; closed loop system; current control system; guaranteed stability; linear matrix inequalities; overmodulation region; permanent magnet synchronous generators; Control systems; Current control; Linear matrix inequalities; Power harmonic filters; Pulse width modulation; Rectifiers; Synchronous generators; Synchronous motors; Vectors; Voltage; Current control; Harmonic compensation; Linear matrix inequalities; Overmodulation; Stability analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference, 2009. COBEP '09. Brazilian
  • Conference_Location
    Bonito-Mato Grosso do Sul
  • ISSN
    2175-8603
  • Print_ISBN
    978-1-4244-3369-8
  • Electronic_ISBN
    2175-8603
  • Type

    conf

  • DOI
    10.1109/COBEP.2009.5347647
  • Filename
    5347647