• DocumentCode
    2593
  • Title

    Novel Sensorless Control Strategy With Injection of High-Frequency Pulsating Carrier Signal Into Stationary Reference Frame

  • Author

    Liu, J.M. ; Zhu, Z.Q.

  • Author_Institution
    Dept. of Electron. & Electr. Eng., Univ. of Sheffield, Sheffield, UK
  • Volume
    50
  • Issue
    4
  • fYear
    2014
  • fDate
    July-Aug. 2014
  • Firstpage
    2574
  • Lastpage
    2583
  • Abstract
    In this paper, a novel sensorless control strategy with the injection of a high-frequency pulsating carrier signal into a stationary reference frame is proposed. Differing from the two most commonly used conventional high-frequency carrier signal injection methods, i.e., the injection of a rotating carrier voltage into a stationary reference frame and the injection of a pulsating carrier voltage into an estimated synchronous reference frame, the new proposed strategy injects a pulsating high-frequency carrier voltage into a stationary reference frame, which is as stable as the rotating carrier signal injection method. Then, the rotor position information can be retrieved from the carrier current response that is amplitude-modulated by the machine saliency, which is as simple as the pulsating carrier signal injection method. The signal demodulation process, the compensation of the cross-saturation effect, and magnetic polarity detection are also discussed and analyzed in detail. The experimental results on an interior permanent-magnet synchronous machine demonstrate that the new proposed strategy has a robust magnetic polarity detection and that it can achieve an accurate rotor position estimation with good steady-state performance and dynamic performance.
  • Keywords
    permanent magnet machines; rotors; sensorless machine control; amplitude-modulated; carrier current response; cross-saturation effect compensation; high-frequency pulsating carrier signal injection; interior permanent-magnet synchronous machine; machine saliency; magnetic polarity detection; rotating carrier voltage injection; rotor position estimation; sensorless control strategy; signal demodulation process; stationary reference frame; synchronous reference frame; Current measurement; Demodulation; Magnetic flux; Mathematical model; Rotors; Saturation magnetization; Sensorless control; Carrier signal injection; PMSM; carrier signal injection; magnetic polarity detection; permanent-magnet synchronous machines (PMSMs); saliency; sensorless;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2013.2293000
  • Filename
    6676793