Title :
Improving short and long term stability of pulsed optically pumped vapor cell frequency standards
Author :
Micalizio, S. ; Godone, A. ; Levi, F. ; Calosso, C.
Author_Institution :
INRIM - Ist. Naz. di Ricerca Metrologica, Torino, Italy
Abstract :
In this paper we discuss how to improve both short and medium-long term frequency stability of a vapor cell frequency standard working in pulsed regime. We propose in particular a multi-step pumping technique that is able to put almost all the atoms in one of the two clock levels, increasing in this way the signal-to-noise ratio with respect to the usual optical pumping made with a single laser pulse. Moreover, we discuss the phenomena affecting the medium-long term frequency stability and how it is possible to control them, making the overall clock stability compatible with sigmay(tau) =3x10-13 tau-frac12 for integration times up to tau = 105 s.
Keywords :
atomic clocks; frequency stability; frequency standards; masers; optical pumping; frequency stability; laser pulse; multistep pumping technique; optical pumping; pulsed optically pumped vapor cell frequency standard; Atom optics; Atomic beams; Clocks; Frequency; Laser excitation; Optical pulses; Optical pumping; Pulsed laser deposition; Signal to noise ratio; Stability;
Conference_Titel :
Frequency Control Symposium, 2009 Joint with the 22nd European Frequency and Time forum. IEEE International
Conference_Location :
Besancon
Print_ISBN :
978-1-4244-3511-1
Electronic_ISBN :
1075-6787
DOI :
10.1109/FREQ.2009.5168342