DocumentCode :
2593639
Title :
Comparison on the test results between reverberation chamber and anechoic chamber
Author :
Zhang Bo ; Yuan Zhiyong ; He Jinliang
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear :
2012
fDate :
21-24 May 2012
Firstpage :
769
Lastpage :
772
Abstract :
Electromagnetic reverberation chamber has been widely used in EMC test. This paper compares the test results in reverberation chamber with those in anechoic chamber by using a simple PCB. The radiated immunity test results in the reverberation chamber are consistent with those in anechoic chamber. The problems of the radiated emission test in the reverberation chamber are analyzed. Feasibility of the substitution method for the total radiated power test in reverberation chamber is investigated by real test. It shows that the influence of the shape and the radiating direction of the EUT on the measured total-radiated power in reverberation chamber is very small. Thus, it is possible to substitute the EUT by standard antennas and the substitution method can be used to measure the total-radiated power in reverberation chamber.
Keywords :
anechoic chambers (electromagnetic); antenna testing; immunity testing; printed circuits; reverberation chambers; EMC test; EUT; PCB; anechoic chamber; electromagnetic reverberation chamber; radiated immunity test; radiated power measurement; standard antenna; substitution method; Antenna measurements; Antennas; Immunity testing; Q measurement; Standards; Systematics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (APEMC), 2012 Asia-Pacific Symposium on
Conference_Location :
Singapore
Print_ISBN :
978-1-4577-1557-0
Electronic_ISBN :
978-1-4577-1558-7
Type :
conf
DOI :
10.1109/APEMC.2012.6237860