DocumentCode :
2593965
Title :
Non-Uniform Field Breakdown of Ar +SF6 under Negative Polarity Impulse Voltages
Author :
Hiziroglu, H.R. ; Dincer, M.S.
Author_Institution :
Dept. of Electr. & Comput. Eng., Kettering Univ., Flint, MI
fYear :
2008
fDate :
26-29 Oct. 2008
Firstpage :
548
Lastpage :
551
Abstract :
In this study, negative-polarity, standard lightning impulse voltages with different magnitudes were employed throughout the experiments. The percentage of SF6 in Ar was varied from 1% to 90% and from 1% to 75% at a total gas pressure of 50 kPa and 100 kPa, respectively. The breakdown voltage of each gas mixture was recorded at 50% breakdown probability. Similar to earlier studies under static electric fields it is observed that the breakdown voltages of Ar+SF6 has increased dramatically when mixed with a small percentage of SF6 under impulse voltages. However, the breakdown voltages were found to be higher than positive polarity, non-uniform and uniform fields.
Keywords :
SF6 insulation; argon; electric breakdown; Ar; negative polarity standard lightning impulse voltages; nonuniform field breakdown voltage; pressure 100 kPa; pressure 50 kPa; Argon; Breakdown voltage; Circuit testing; Electric breakdown; Electrodes; Lightning; Nonuniform electric fields; Oscilloscopes; Steel; Sulfur hexafluoride;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2008. CEIDP 2008. Annual Report Conference on
Conference_Location :
Quebec, QC
Print_ISBN :
978-1-4244-2548-8
Electronic_ISBN :
978-1-4244-2549-5
Type :
conf
DOI :
10.1109/CEIDP.2008.4772763
Filename :
4772763
Link To Document :
بازگشت