• DocumentCode
    2596279
  • Title

    A reconfiguration technique for cascaded H-bridge multilevel inverter drives

  • Author

    Khomfoi, Surin

  • Author_Institution
    Dept. of Electr. Eng., King Mongkut´´s Inst. of Technol. Ladkrabang, Bangkok
  • Volume
    2
  • fYear
    2008
  • fDate
    14-17 May 2008
  • Firstpage
    993
  • Lastpage
    996
  • Abstract
    A reconfiguration technique for cascaded H-bridge multilevel inverter drives (CMID) is proposed in this paper. The reliability of the CMID can be improved by using the proposed reconfiguration technique. The proposed technique is very simple to implement because the proposed technique is based on digital logic gate; a simple AND gate and OR gate can be implemented for this reconfiguration method. The effects and limitations of using the developed reconfiguration technique at high modulation index are also addressed.
  • Keywords
    invertors; logic gates; power system reliability; AND gate; CMID; OR gate; cascaded H-bridge multilevel inverter drives; digital logic gate; reliability; Batteries; Circuit faults; Hybrid electric vehicles; Inverters; Logic gates; Modulation; Reconfigurable logic; Semiconductor diodes; Traction motors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, 2008. ECTI-CON 2008. 5th International Conference on
  • Conference_Location
    Krabi
  • Print_ISBN
    978-1-4244-2101-5
  • Electronic_ISBN
    978-1-4244-2102-2
  • Type

    conf

  • DOI
    10.1109/ECTICON.2008.4600599
  • Filename
    4600599