Title :
Interference mechanism of external current on heavy current transformer
Author :
Kaifeng Qu ; Wei Zhao ; Peng Yang ; Songling Huang ; Bo Jiang
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
Abstract :
In order to reduce the interference from stray flux of adjacent bus bars on the error of heavy current transformer (HCT) which always has a large diameter, the interference mechanism was investigated theoretically in details based on magnetic circuit. It was concluded that there were mainly two interference ways that the stray flux affected the error of HCT, and then it was further verified by experiments and finite element method (FEM). A formula was derived to calculate the error of HCT due to the interference. It was found that leakage flux around the core performed an important role in the error of HCT with a large diameter. Some methods were suggested to reduce the interference on HCT, especially when considering the nonuniform leakage flux along the large circumference of iron core.
Keywords :
current transformers; electromagnetic interference; finite element analysis; magnetic cores; bus bars; electromagnetic fields.; error calculation; external current interference mechanism; finite element method; heavy current transformer; interference reduction; iron core; magnetic circuit; power stations; stray flux; Bars; Coils; Current transformers; Finite element methods; Inductance; Interference; Magnetic analysis; Magnetic circuits; Power generation; Transformer cores; error; heavy current transformer; leakage flux; shielding coils; stray flux;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
Conference_Location :
Singapore
Print_ISBN :
978-1-4244-3352-0
DOI :
10.1109/IMTC.2009.5168647