Abstract
For the signal containing the inter-harmonics, if the sample number is not equal to integer times of the signal period, the spectral leakages will occur in harmonic analysis based on DFT and affect the measurement accuracy. To improve the accuracy, different from other correction methods in which the long-range leakages are reduced by windowing the signal, a new interpolation algorithm is presented to correct both the long-range leakage and the short-range leakage at one time. The simulation results and experiment results show the measurement accuracy of the presented method is very high. The new algorithm is suitable for the precise harmonic analysis.
Keywords
discrete Fourier transforms; harmonic analysis; interpolation; signal sampling; spectral analysis; DFT; correction method; discrete Fourier transform; interharmonic analysis; interpolation algorithm; precise measurement method; signal sampling; spectral leakage; Discrete Fourier transforms; Electric variables measurement; Frequency measurement; Harmonic analysis; Instrumentation and measurement; Interpolation; Phase measurement; Power system harmonics; Sampling methods; Signal sampling; DFT; accuracy; interpolation algorithm; leakage;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
Conference_Location
Singapore
ISSN
1091-5281
Print_ISBN
978-1-4244-3352-0
Type
conf
DOI
10.1109/IMTC.2009.5168708
Filename
5168708
Link To Document