  • Abstract
    In this paper we present the influence of the load position, represented by a metallic cube, inside the uniform zone of a compact reverberation chamber when it is placed asymmetrically to the chamber´s wall. The measurement standard test of the uniform zone requires an empty chamber. The measurements of the chamber statistical electrical field uniformity are made accordingly the IEC61004-21 standard. Unfortunately, no guarantee of the field uniformity is assured when the equipment is positioned inside.
  • Keywords
    IEC standards; electric field measurement; electromagnetic compatibility; measurement standards; reverberation chambers; IEC61004-21 standard; asymmetrically positioned load; chamber statistical electrical field uniformity measurements; electromagnetic compatibility; measurement standard test; metallic cube; reverberation chamber; Calibration; Electric variables measurement; Electromagnetic measurements; IEC standards; Instrumentation and measurement; Measurement standards; Resonance; Reverberation chamber; Testing; Volume measurement; Reverberation chamber; asymmetric position; electrical field uniformity; position influence; quasi-isotropic probe;
  • fLanguage