Title :
Measurement of the pupil diameter under different light stimula
Author :
Masi, Maria Gabriella ; Peretto, Lorenzo ; Tinarelli, Roberto ; Rovati, Luigi
Author_Institution :
Dipt. di Ing. Elettr., Univ. di Bologna, Bologna, Italy
Abstract :
The subjectivity and the limitation of the standard method for the flicker evaluation have suggested the research of different approaches. The intent is to achieve objective information on the state of annoyance of a human being subjected to light flicker. Recently, a technique based on the analysis of the pupil size variation has been proposed. This paper studies the effects of different light stimula on pupil diameter and highlight some interesting results.
Keywords :
diameter measurement; eye; flicker noise; human being annoyance state; human pupil diameter measurement; light flicker evaluation; light stimula condition; pupil size variation analysis; Cameras; Data acquisition; Frequency; Humans; Instruments; Light emitting diodes; Measurement standards; Microcomputers; Voltage fluctuations; Wavelength measurement;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
Conference_Location :
Singapore
Print_ISBN :
978-1-4244-3352-0
DOI :
10.1109/IMTC.2009.5168720