• DocumentCode
    2601772
  • Title

    A Comparison of 1% MgAl and 1% SiAl Wire Interconnects

  • Author

    Pankratz, J.M. ; Collins, D.R.

  • Author_Institution
    Texas Instruments Incorporated, Dallas, Texas 75222
  • fYear
    1970
  • fDate
    25659
  • Firstpage
    163
  • Lastpage
    169
  • Abstract
    Ultrasonically bonded interconnects have been made to semiconductor devices with both 1% SiAl and 1% MgAl wire. This investigation indicates that 1% MgAl wire is not a dominant cause of electrical degradation in any device studied. On the other hand, the effects of annealing time ue to 1000 hours and annealing temperature up to 300°C on the strength of the wire demonstrate the mechanical superiority of the 1% MgAl wire. The two types of wire have a similar behavior in relation to the effects of ultrasonic power and time on wire deformation and bond strength. A critical amount of energy input, as evidenced by wire deformation, is necessary for a strong bond, and further deformation weakens the interconnection. This investigation indicated that the one mil, 1% MgAl wire has potentially higher reliability than the 1% SiAl wire.
  • Keywords
    Annealing; Bonding; Degradation; Failure analysis; Mechanical factors; Semiconductor devices; Silicon; Temperature; Testing; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1970. 8th Annual
  • Conference_Location
    Las Vegas, NV, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1970.362453
  • Filename
    4207819