DocumentCode
2606573
Title
Hermeticity and Particle Impact Noise Test Techniques
Author
McCullough, Ralph E.
Author_Institution
Texas Instruments Incorporated, Dallas, Texas 75222
fYear
1976
fDate
27851
Firstpage
256
Lastpage
262
Abstract
Factors to be considered in selecting a hermetic seal test technique are reviewed and discussed. These include package size and condition as well as the objectives of the testing. Also factors which may contribute to result error and wrong conclusions are examined. Why they cause error and the type of results one should be suspicious of are discussed. The effects of shock levels, vibration level and frequency on particle detection using the impact noise technique are reviewed. Also methods of attaching devices to the transducer are discussed. Positive actions that can be taken to improve the results of hermeticity and particle detection test are also pointed out.
Keywords
Delay effects; Electric shock; Failure analysis; Frequency; Helium; Hermetic seals; Instruments; Noise level; Packaging machines; Testing;